Using our knowledge we can show you how to make savings.
Dürr Technik are leaders in the field of Oil-free compressor technology and for many years have provided high quality equipment to breweries, pub companies, and restaurant groups, everywhere where beverages are dispensed - from small family business to large stadiums.
Advantages:
Using a modern dispensing system:
Applications for Dürr Technik compressors:
Type | Delivery- rate at 0 bar |
Nominal pressure |
Sound-pressure level at PN |
Characteristics of the motor | receiver | Dimensions | |
Motor- performance |
current- consumption |
||||||
(l/min) | PN (bar) | dB (A) | P1(W) | (A) | (l) | L x B x H (mm) | |
UA-025 | 25 | 7 | 55 | 220 | 1,0 | 3 | 320 x 320 x 320 |
WA-0381 | 38 | 7 | 57 | 300 | 1,5 | 10 | 550 x 180 x 430 |
WA-038 AK2 | 38 | 7 | 57 | 300 | 1,5 | 10 | 550 x 180 x 430 |
1) with mechanical start-up and manual condensate drainage.
2) with electrical start-up solenoid valve and automatical condensate drainage with timer
voltage = 230 V
frequency = 50/60 Hz
protection class = 54 IP (UA-025 = 44 IP)
Type | Delivery- rate at 0 bar |
Nominal pressure |
Sound-pressure level at PN |
Characteristics of the motor | receiver | Dimensions | |
Motor- performance |
current- consumption |
||||||
(l/min) | PN (bar) | dB (A) | P1(W) | (A) | (l) | L x B x H (mm) | |
TA-038 K | 38 | 7 | 57 | 310 | 1,5 | 25 | 615 x 353 x 510 |
TA-065 K | 65 | 7 | 67 | 620 | 2,7 | 25 | 615 x 353 x 555 |
TA-100 AK | 110 | 8 | 68 | 920 | 4,9 | 25 | 615 x 353 x 630 |
TAG-132 AK | 130 | 7 | 70 | 990 | 4,3 | 25 | 615 x 353 x 510 |
This range of air compressor stations have automatic condensate drain valves as standard.
Further accessories are available on request.
voltage = 230 V
frequency = 50/60 Hz
protection class = 54 IP
Typ | Size of vessel in litre |
Number of pumps* | Max. dispensed volumes supported |
UA-025 | 3 | 1 | 2 |
WA-038 | 10 | 2 | 4 |
TA-038 | 25 | 2 | 4 |
TA-061 | 25 | 4 | 8 |
TA-065 | 25 | 4 | 8 |
TA-100K | 25 | 8 | 16 |
TAG-132 | 25 | 9 | 18 |
TA-200K | 25 | 16 | 32 |
* Please note:
the number of pumps is based on the following drive pressure = 2.5 bar and a continuous dispense speed of 2 l/min. Air consumption = 12 l /min/pump
The determining factor is the maximum dispensed volumes supported, independent of the number of connected pumps. E.g. a UA-025 is sufficient to drive 5 pumps if the maximum dispense volumes are less than 2l/min at peak time.
In general the number of connected pumps depends on:
File name | Size |
---|---|
Getraenkeindustrie_DE.pdf | (1.0 MiB) |
Beverage_GB.pdf | (1.3 MiB) |
Beverage_FR.pdf | (1.4 MiB) |
Beverage_SP.pdf | (1.3 MiB) |
Beverage_RU.pdf | (1.1 MiB) |
Python Care_DE.pdf | (361.7 KiB) |
Python Care_GB.pdf | (361.1 KiB) |
Python Care_Sicherheitsdatenblatt_DE.pdf | (79.4 KiB) |
Python Care_Safety Datasheet_GB.pdf | (82.6 KiB) |
Python Care_Fiche de donnees de securite_FR.pdf | (103.9 KiB) |
Python Care_Weisung_Strassenverkehr.pdf | (494.3 KiB) |