Gasrückführungspumpen
PRODUCTS > Industry solutions > Vapor recovery

Leading by Our Experience

Consultation, development and production from one source for economical system solutions

Vapour Recovery phase II is stipulated by law in many European countries. The objective is to return the petrol vapour back into the storage tank, which otherwise will exhaust into the environment when re-fuelling a car. Consequently vapour recovery systems complete with vapour recovery pumps are installed into the fuel forecourt-dispensing pump.

In Germany, since the beginning of 2003 the vapour recovery systems have been additionally equipped with a vapour recovery monitoring system. The purpose of this additional process is to detect problems promptly so reducing pump down time and ensuring a constantly high vapour recovery rate.

Dürr’s vapour recovery pump is a proven standard product providing a trouble-free operating vapour recovery system. A constant flow volume is maintained throughout the whole lifetime of the pump. The following diagram shows the main components of a typical vapour recovery system without vapour recovery monitoring.

Operating Mode:
The process is based on regulating the flow volume percentage of the dispensed petrol to the petrol vapour exhausted. The ratio is adjusted to 1:1 (proportionally) and controlled by a mechanical (1) or electric (2) proportional valve. Proportional valves are not required for systems with a speed control (3).

Advantages of the MEX-Vapour

  • Long service life
  • Patented pre-chamber with drainage system guaranteeing resistance against condensate and liquid
  • Self-adjusting piston lining for a constant volume flow throughout the whole lifetime
  • Wide temperature operating range - 40 °C to +60 °C
  • Small and robust, suitable for installation at the manufacturer or retrofitting
  • Suitable to work with either mechanical or electric proportional valves
  • A choice of drives:
    - belt or coupling drive (MEX 0831-11, 0831-10)
    - direct drive (MEX 0544)
  • Motors 50 Hz and 60 Hz, for worldwide operation
  • Integrated flame arresters at the in and outlet ensuring maximum safety
  • Suitable also as flame trap in vapour recovery systems
  • Various fitting positions possible
  • Rotational direction independent of pump orientation
  • Materials appropriate for applications with „E85“
Technical Data - Belt Drive (0831-10 / 0831-11)

Advantages:

  1. ATEX and TÜV Certificated
  2. Oil- and maintenance free
  3. Resistant to condensate and liquid
  4. Rotation independent of pump orientation
  5. Noise level

Belt Drive

Volume flow*

pabs
min

Motor Power
recommended
Maximal
allowed
speed
Dimensions
  V (l/min) (mbar) (W) (1/min) L x W x H (mm)
0831-10
43
˜ 150
150 (200)
2100
148 x 88 x 188
0831-11 44 ˜ 150 150 (200) 2300 148 x 88 x 188

Accessory:
belt pulley (94 mm effective diameter) Replacement pumps and motors on request.

Remarks:
V = volume flow at back pressure pe = 150 mbar
suction pressure pabs = 900 mbar Medium: Air
pabs = absolute pressure
Ls = noise level based on EN ISO 2151 and EN ISO 3744

Technical Data - Direct Drive 1-Cylinder (0544 1_ _ _)
  1. ATEX and TÜV Certificated
  2. Oil- and maintenance free
  3. Resistant to condensate and liquid
  4. Rotation independent of pump orientation
  5. Noise level
  6. Protection class IP 10
Volume
flow*
pabs
min
Relay Characteristic of the motors
Dimensions
Motor
input
IN UN F
  V (l/min) (mbar)
(V) P1 (W) (A) (V) (Hz) L x W x H (mm)
0544 1000 53 ˜ 150 24 DC 285-312 0,75 380-415 50 310 x 152 x 201
0544 1100 53 ˜ 150 non 285-312 0,75 380-415 50 310 x 152 x 201
0544 1200 53 ˜ 150 24 DC 440-480 2,20 200-240 50 365 x 152 x 201
0544 1250 53 ˜ 150 220-240AC 310 1,35 230 50 315 x 152 x 201
0544 1300 53 ˜ 150 non 440-480 2,20 200-240 50 365 x 152 x 201
0544 1400 38 ˜ 150 24 DC 200-230 1,80 110-127 60 365 x 152 x 201
0544 1500 38 ˜ 150 non 200-230 1,80 110-127 60 365 x 152 x 201
0544 1700 53 ˜ 150 220-240AC 285-312 0,75 380-415 50 310 x 152 x 201
0544 1800 38 ˜ 150 non 250 1,15 220 60 365 x 152 x 201

Remarks:
V = volume flow at back pressure pe = 150 mbar
suction pressure pabs = 900 mbar
Medium: Air
pabs = absolute pressure
Ls = noise level based on EN ISO 2151 and EN ISO 3744
IN = nominal current    UN = nominal voltage    f = frequency

Technical Data - Direct Drive 2-Cylinder (0544 2_ _ _)
  1. ATEX and TÜV Certificated
  2. Oil- and maintenance free
  3. Resistant to condensate and liquid
  4. Rotation independent of pump orientation
  5. Noise level
  6. Protection class IP 10
Volume
flow*
pabsmin Relay Characteristic of the motors
Dimensions
Motor
input
IN UN F
  V (l/min) (mbar)
(V) P1 (W) (A) (V) (Hz) L x W x H (mm)
0544 2000 53 ˜ 150 24 DC 340-375 0,90 380-415 50 432 x 152 x 201
0544 2100 53 ˜ 150 non 340-375 0,90 380-415 50 432 x 152 x 201
0544 2200 53 ˜ 150 24 DC 660-720 3,00 220-240 50 487 x 152 x 201
0544 2300 53 ˜ 150 non 660-720 3,00 220-240 50 487 x 152 x 201
0544 2400 53 ˜ 150 24 DC 320-370 2,90 110-127 60 487 x 152 x 201
0544 2500 38 ˜ 150 non
320-370 2,90 110-127 60 487 x 152 x 201
0544 2700 53 ˜ 150 220-240AC 340-375 0,90 380-415 50 432 x 152 x 201
0544 2800 38 ˜ 150 non 330 1,50 220 60 487 x 152 x 201

Remarks:
V = volume flow at back pressure pe = 150 mbar
suction pressure pabs = 900 mbar
Medium: Air
pabs = absolute pressure
Ls = noise level based on EN ISO 2151 and EN ISO 3744
IN = nominal current    UN = nominal voltage    f = frequency